中層貧酸素化の軽減を目的とした貯水池曝気施設の計画

書誌事項

タイトル別名
  • PLANNING OF AERATION SYSTEM FOR MINIMIZING DEOXYGENATION IN RESERVOIR METALIMNION

抄録

It was found in a eutrophic reservoir that the metalimnion became anoxic during the hot season while the hypolimnion became successfully aerated. As countermeasures against deoxygenation of the reservoir metalimnion, performance of three types of aeration systems, i. e. (i) air diffuser system, (ii) air bubbler destratification system and (iii) air bubble jet system, was evaluated by making a numerical analysis of water quality. In the analysis, physical processes such as dissolved oxygen dilution and vertical mixing caused by aeration were taken into consideration in addition to hydrodynamics and biochemical processes regarding to water quality. The system's performance was examined from view points not only of water purification but also of cost-benefit performance. It was found through the analysis that the air bubbler destratification system shows the best performance. System's capacity necessary for the aeration was also discussed.

収録刊行物

  • 水工学論文集

    水工学論文集 51 1355-1360, 2007

    公益社団法人 土木学会

被引用文献 (1)*注記

もっと見る

関連プロジェクト

もっと見る

詳細情報 詳細情報について

  • CRID
    1390001205170986240
  • NII論文ID
    130003842413
  • DOI
    10.2208/prohe.51.1355
  • ISSN
    18849172
    09167374
  • データソース種別
    • JaLC
    • Crossref
    • CiNii Articles
    • KAKEN
  • 抄録ライセンスフラグ
    使用不可

問題の指摘