A Simple and Rapid In Situ Preconcentration Method for the Determination of Fluoride Ion in Environmental Water Using Solid-Phase Extraction
-
- Okumura Minoru
- <I>Department of Material Science, Faculty of Science and Engineering, Shimane University</I>
-
- Yoshimura Tomohiro
- <I>Department of Material Science, Faculty of Science and Engineering, Shimane University</I>
-
- Seike Yasushi
- <I>Department of Material Science, Faculty of Science and Engineering, Shimane University</I>
-
- Fujinaga Kaoru
- <I>Kanazawa Institute of Technology</I>
Abstract
A simple and rapid in situ preconcentration method for the determination of fluoride ion in environmental water has been developed based on solid-phase extraction using a zirconium-loaded Sep-Pak Accell CM (Zr-SP) . The adsorption of fluoride ion and its desorption depend only on the pH of solution. A water sample (pH 2) containing fluoride ion was passed through a Zr-SP to collect it. The retained fluoride ion was quantitatively eluted with 0.1 M sodium hydroxide solution. The established preconcentration method was successfully applied to environmental water such as brackish water, river water and rain water.
Journal
-
- Journal of Ion Exchange
-
Journal of Ion Exchange 18 (4), 518-523, 2007
Japan Society of Ion Exchange
- Tweet
Details 詳細情報について
-
- CRID
- 1390001204434676736
-
- NII Article ID
- 130004162483
-
- COI
- 1:CAS:528:DC%2BD1cXnsVKmtb0%3D
-
- ISSN
- 18843360
- 0915860X
- http://id.crossref.org/issn/0915860X
-
- Text Lang
- en
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed