モノエタノールアミン溶液によるH-3とC-14の同時捕集における温湿度の影響 [in Japanese] Influence of Air Temperature and Humidity on Simultaneous Collection of H-3 and C-14 by Mono-ethanolamine Solution [in Japanese]
Access this Article
Author(s)
Abstract
Lumagel Plus scintillator was selected as the most suitable scintillator for simultaneous collection of H-3 and C-14 by using mono-ethanolamin (MEA) solution.The influence of air temperature and humidity on the collection efficien cy of H-3 and C-14 was examined.As the result, when the weight of water in MEA was less than 1000mg, the samples became colorless without separation into two phases, and the collection efficiency of 99% and more was obtained for C-14 within the collection time of 3.7 hours.On the other hand, the collection efficiency for H-3 decreased with increase of the weight of water in the collected air, but it was more than 90% even at high temperature of 30°C and high relative humidity of 90%.It was found that this method is practically useful for simultaneous determination of H-3 and C-14 concentration in air.
Journal
-
- Japanese Journal of Radiation Safety Management
-
Japanese Journal of Radiation Safety Management 7(2), 158-162, 2008
JAPANESE SOCIETY OF RADIATION SAFETY MANAGEMENT