Study of sloshing control method with damping device of actual floating roof tank
Bibliographic Information
- Other Title
-
- 浮屋根式実機タンクを用いてのスロッシング制振装置の性能評価
Abstract
The liquid sloshing of oil storage tanks caused by Tokachi-Oki earthquake in 2003 gave severe damage to oil tanks in Tomakomai area. The purpose of our study is to propose damping method against liquid sloshing so that damage and sink of floating roofs of the oil tanks can be prevented. In this paper, we propose the buffer using viscoelastic materials as for anti-liquid sloshing measure and have confirmed that the buffer damping method is appropriate to damp liquid sloshing for actual floating roof tank.
Journal
-
- Journal of Japan Society of Civil Engineers, Ser. A2 (Applied Mechanics (AM))
-
Journal of Japan Society of Civil Engineers, Ser. A2 (Applied Mechanics (AM)) 67 (2), I_935-I_943, 2011
Japan Society of Civil Engineers