試薬および環境中のオスミウムブランク低減についての試み:ブランク測定方法と起源の解明  [in Japanese] Osmium in reagents and environment: implication for measurements of low level Os and identification of the sources of Os blanks  [in Japanese]

Access this Article

Author(s)

    • 仙田 量子 Senda Ryoko
    • 独立行政法人海洋研究開発機構 地球内部ダイナミクス領域 Institute for Research on Earth Evolution (IFREE), Japan Agency for Marine-Earth Science and Technology (JAMSTEC)
    • 石川 晃 Ishikawa Akira
    • 独立行政法人海洋研究開発機構 地球内部ダイナミクス領域|東京大学大学院総合文化研究科 Institute for Research on Earth Evolution (IFREE), Japan Agency for Marine-Earth Science and Technology (JAMSTEC)|Department of Earth Science and Astronomy, The University of Tokyo

Abstract

白金族元素の一つであるオスミウム(Os)の放射性同位体(<sup>187</sup>Os/<sup>188</sup>Os)比の高精度・高確度分析には,化学分離操作に伴うブランクの低減が最重要である.本研究ではICP-QMSによるスパージング法を適用し,Osの分離濃縮に使用する各種試薬のOsブランクを測定することにより,その起源の特定を試みた.その結果,主なブランク源は岩石粉末試料の分解の際に使用する硝酸と環境中に浮遊して存在するOsであることが判明した.硝酸については,硝酸の酸化剤としての性質を生かした高温での蒸発や窒素や空気のガスを通じつつ加熱を行う方法で硝酸内のOsを揮発性の高い四酸化Osとして除去し,Osブランクを半減させることができた.環境中のブランクについては,実験室の空気圧をあげることでOsを多量に使用する他の実験室からの空気流入量を制限するとともに,溶液の蒸発乾固を閉鎖環境で行うことなどで試料への混入を最小限にとどめた.これらの結果,現在では数pptレベルのOs分析が可能になるほどOsブランクを減少させることが可能となった.

Blank level during the analytical process is critical for the determination of Os isotope ratios (<sup>187</sup>Os/<sup>188</sup>Os) both for high precision and accuracy. Previously, the blank level in the PGE laboratory was not good enough to measure samples with very low Os contents. To improve the blank level, we measured Os blanks in each reagent used in Os isotope analytical procedures by sparging method with ICP-QMS and tried to identify the source of Os blanks. Two major sources of Os blanks were identified; one is from nitric acid which is used in the digestion of samples, and the other is from environmental Os in the laboratory. We were able to decrease the Os blank in nitric acid to 1/3~1/2 than the original by heating and bubbling Air and N<sub>2</sub> gas into the nitric acid. To reduce the blank contribution from environmental Os, we used closed vaporization system during the evaporation of HBr sample solution. The closed vaporization system is quite efficient to prevent the air containing environmental Os for reducing the Os blanks. As a result, the Os blank level in our laboratory was reduced significantly for the analysis of ppt-level samples.

Journal

  • JAMSTEC Report of Research and Development

    JAMSTEC Report of Research and Development 18(0), 17-28, 2014

    Japan Agency for Marine-Earth Science and Technology