A Preliminary Study on Low-dose X-ray Imaging Using Parametric X-ray
-
- Sakae Toshiro
- Department of Histology, Nihon University School of Dentistry at Matsudo LEBRA, Laboratory for Electron Beam Research and Application, Institute of Quantum Science, Nihon University
-
- Hayakawa Yasushi
- LEBRA, Laboratory for Electron Beam Research and Application, Institute of Quantum Science, Nihon University
-
- Takahashi Yumiko
- LEBRA, Laboratory for Electron Beam Research and Application, Institute of Quantum Science, Nihon University
-
- Kuwada Takao
- LEBRA, Laboratory for Electron Beam Research and Application, Institute of Quantum Science, Nihon University
-
- Nakao Keisuke
- LEBRA, Laboratory for Electron Beam Research and Application, Institute of Quantum Science, Nihon University
-
- Nogami Kyoko
- LEBRA, Laboratory for Electron Beam Research and Application, Institute of Quantum Science, Nihon University
-
- Inagaki Manabu
- LEBRA, Laboratory for Electron Beam Research and Application, Institute of Quantum Science, Nihon University
-
- Tanaka Toshinari
- LEBRA, Laboratory for Electron Beam Research and Application, Institute of Quantum Science, Nihon University
-
- Sato Isamu
- LEBRA, Laboratory for Electron Beam Research and Application, Institute of Quantum Science, Nihon University
-
- Hirayama Katsunori
- Department of Histology, Nihon University School of Dentistry at Matsudo
-
- Sekiya Kotarou
- Department of Radiology, Nihon University School of Dentistry at Matsudo
-
- Kaneda Takashi
- Department of Radiology, Nihon University School of Dentistry at Matsudo
-
- Suemitsu Masaaki
- Department of Oral Pathology, Nihon University School of Dentistry at Matsudo
-
- Okada Hiroyuki
- Department of Oral Pathology, Nihon University School of Dentistry at Matsudo
-
- Yamamoto Hirotsugu
- Department of Oral Pathology, Nihon University School of Dentistry at Matsudo
-
- Hata Saya
- Department of Oral Surgery, Nihon University School of Dentistry at Matsudo
-
- Akimoto Yoshiaki
- Department of Oral Surgery, Nihon University School of Dentistry at Matsudo
-
- Fukumoto Masahiko
- Department of Clinical Pathology, Nihon University School of Dentistry at Matsudo
-
- Makimura Masaharu
- Department of Clinical Pathology, Nihon University School of Dentistry at Matsudo
Abstract
Parametric X-ray (PXR) is a new type of radiography with variable monochrome wavelength and high coherent characteristics. The Laboratory for Electron Beam Research and Application (LEBRA) at Quantum Science Institute, Nihon University generated LEBRA-PXR, a system that irradiates Si crystal with electron accelerated by linear accelerator (LINAC). LEBRA-PXR is uniquely developed for world-wide application experiment. X-ray images of tooth samples were taken with flat panel detector using LEBRA-PXR. As a result, images were captured as short as 1 sec. LEBRA-PXR uses LINAC with micro-macro pulse electron beam structure. Imaging time of 1 sec is equivalent to about 0.025 msec when x-ray is converted to actual radiation exposure. The effective dose point estimates of x-rays were about 1 μ Sv/5 sec. Results show that LEBRA-PXR can be used to generate low dose x-ray imaging advocating the possibility of its application in biological studies and medical treatment.
Journal
-
- Journal of Hard Tissue Biology
-
Journal of Hard Tissue Biology 20 (1), 31-36, 2011
THE SOCIETY FOR HARD TISSUE REGENERATIVE BIOLOGY
- Tweet
Details 詳細情報について
-
- CRID
- 1390282679435425792
-
- NII Article ID
- 130004848361
-
- ISSN
- 1880828X
- 13417649
-
- Text Lang
- en
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
- KAKEN
-
- Abstract License Flag
- Disallowed