A Preliminary Study on Low-dose X-ray Imaging Using Parametric X-ray

  • Sakae Toshiro
    Department of Histology, Nihon University School of Dentistry at Matsudo LEBRA, Laboratory for Electron Beam Research and Application, Institute of Quantum Science, Nihon University
  • Hayakawa Yasushi
    LEBRA, Laboratory for Electron Beam Research and Application, Institute of Quantum Science, Nihon University
  • Takahashi Yumiko
    LEBRA, Laboratory for Electron Beam Research and Application, Institute of Quantum Science, Nihon University
  • Kuwada Takao
    LEBRA, Laboratory for Electron Beam Research and Application, Institute of Quantum Science, Nihon University
  • Nakao Keisuke
    LEBRA, Laboratory for Electron Beam Research and Application, Institute of Quantum Science, Nihon University
  • Nogami Kyoko
    LEBRA, Laboratory for Electron Beam Research and Application, Institute of Quantum Science, Nihon University
  • Inagaki Manabu
    LEBRA, Laboratory for Electron Beam Research and Application, Institute of Quantum Science, Nihon University
  • Tanaka Toshinari
    LEBRA, Laboratory for Electron Beam Research and Application, Institute of Quantum Science, Nihon University
  • Sato Isamu
    LEBRA, Laboratory for Electron Beam Research and Application, Institute of Quantum Science, Nihon University
  • Hirayama Katsunori
    Department of Histology, Nihon University School of Dentistry at Matsudo
  • Sekiya Kotarou
    Department of Radiology, Nihon University School of Dentistry at Matsudo
  • Kaneda Takashi
    Department of Radiology, Nihon University School of Dentistry at Matsudo
  • Suemitsu Masaaki
    Department of Oral Pathology, Nihon University School of Dentistry at Matsudo
  • Okada Hiroyuki
    Department of Oral Pathology, Nihon University School of Dentistry at Matsudo
  • Yamamoto Hirotsugu
    Department of Oral Pathology, Nihon University School of Dentistry at Matsudo
  • Hata Saya
    Department of Oral Surgery, Nihon University School of Dentistry at Matsudo
  • Akimoto Yoshiaki
    Department of Oral Surgery, Nihon University School of Dentistry at Matsudo
  • Fukumoto Masahiko
    Department of Clinical Pathology, Nihon University School of Dentistry at Matsudo
  • Makimura Masaharu
    Department of Clinical Pathology, Nihon University School of Dentistry at Matsudo

Abstract

Parametric X-ray (PXR) is a new type of radiography with variable monochrome wavelength and high coherent characteristics. The Laboratory for Electron Beam Research and Application (LEBRA) at Quantum Science Institute, Nihon University generated LEBRA-PXR, a system that irradiates Si crystal with electron accelerated by linear accelerator (LINAC). LEBRA-PXR is uniquely developed for world-wide application experiment. X-ray images of tooth samples were taken with flat panel detector using LEBRA-PXR. As a result, images were captured as short as 1 sec. LEBRA-PXR uses LINAC with micro-macro pulse electron beam structure. Imaging time of 1 sec is equivalent to about 0.025 msec when x-ray is converted to actual radiation exposure. The effective dose point estimates of x-rays were about 1 μ Sv/5 sec. Results show that LEBRA-PXR can be used to generate low dose x-ray imaging advocating the possibility of its application in biological studies and medical treatment.

Journal

Citations (3)*help

See more

References(25)*help

See more

Related Projects

See more

Details 詳細情報について

  • CRID
    1390282679435425792
  • NII Article ID
    130004848361
  • DOI
    10.2485/jhtb.20.31
  • ISSN
    1880828X
    13417649
  • Text Lang
    en
  • Data Source
    • JaLC
    • Crossref
    • CiNii Articles
    • KAKEN
  • Abstract License Flag
    Disallowed

Report a problem

Back to top