高齢者向け小規模社会福祉施設の火災に対する安全性に関する研究

書誌事項

タイトル別名
  • ACTUAL CONDITIONS AND PROBLEMS OF FIRE SAFETY IN THE GROUP LIVING FOR THE ELDERLY WITH DEMENTIA AND THE COMMUNITY BASED MULTI-CARE FACILITY
  • コウレイ シャムケケ ショウキボ シャカイ フクシ シセツ ノ カサイ ニ タイスル アンゼンセイ ニ カンスル ケンキュウ

この論文をさがす

抄録

This study clarifies the actual conditions of fire safety of group home for the people with dementia and community based multi-care facility in Japan. The nationwide investigation by questionnaire was conducted. Summaries are as follows. The rate of uninstallation of sprinkler in group home in total floor area 275sq. meters to 1,000 sq. meters is 98.0 percent. In case of total floor area is less than 275sq. meters, the rate is 40.9 percent. The examination of the ideal way of the treatment and the sprinkler equipment in community based multi-care facility, are given as problem.

収録刊行物

被引用文献 (1)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘