Two-Dimensional Distribution of Electron Temperature in Ergodic Layer of LHD Measured from Line Intensity Ratio of CIV and NeVIII

  • WANG Erhui
    Department of Fusion Science, Graduate University for Advanced Studies
  • MORITA Shigeru
    Department of Fusion Science, Graduate University for Advanced Studies National Institute for Fusion Science
  • DONG Chunfeng
    National Institute for Fusion Science
  • GOTO Motoshi
    Department of Fusion Science, Graduate University for Advanced Studies National Institute for Fusion Science
  • MURAKAMI Izumi
    Department of Fusion Science, Graduate University for Advanced Studies National Institute for Fusion Science
  • OISHI Tetsutarou
    Department of Fusion Science, Graduate University for Advanced Studies National Institute for Fusion Science

この論文をさがす

抄録

Two-dimensional distribution of impurity lines emitted from ergodic layer with stochastic magnetic field lines in Large Helical Device (LHD) has been observed using a space-resolved extreme ultraviolet (EUV) spectrometer. The two-dimensional electron temperature distribution in the ergodic layer is successfully measured using the line intensity ratio of Li-like NeVIII 2s-3p (2S1/2-2P3/2: 88.09 Å, 2S1/2-2P1/2: 88.13 Å) to 2p-3s (2P1/2-2S1/2: 102.91 Å, 2P3/2-2S1/2: 103.09 Å) transitions emitted from radial location near Last Closed Flux Surface (LCFS). The intensity ratio analyzed with ADAS code shows no dependence on the electron density below 1014 cm−3. The result indicates a little higher temperature, i.e., 220 eV, in the poloidal location at high-field side near helical coils called O-point compared to the temperature near X-point, i.e., 170 eV. The electron temperature profile is also measured at the edge boundary of ergodic layer using the line intensity ratio of Li-like CIV 2p-3d (2P1/2-2D3/2: 384.03 Å, 2P3/2-2D5/2: 384.18 Å) to 2p-3s (2P1/2-2S1/2: 419.53 Å, 2P3/2-2S1/2: 419.71 Å) transitions. The intensity ratios analyzed with CHIANTI, ADAS and T.Kawachi codes show a slightly higher temperature near O-point, i.e., 25 eV for CHIANTI, 21 eV for ADAS and 11 eV for T.Kawachi’s codes, compared to the temperature at X-point, i.e., 15 - 21 eV for CHIANTI, 9 - 15 eV for ADAS and 6 - 9 eV for T.Kawachi codes. It suggests that the transport coefficient in the ergodic layer is varied with three-dimensional structure.

収録刊行物

  • Plasma and Fusion Research

    Plasma and Fusion Research 8 (0), 2402176-2402176, 2013

    一般社団法人 プラズマ・核融合学会

被引用文献 (1)*注記

もっと見る

参考文献 (3)*注記

もっと見る

関連プロジェクト

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ