MR Contrast in Mouse Lymph Nodes with Subcutaneous Administration of Iron Oxide Particles: Size Dependency

  • MORI Yuki
    Biofunctional Imaging Laboratory, Immunology Frontier Research Center, Annex 1F, Graduate School of Frontier Biosciences, Osaka University Department of Neurosurgery, Iwate Medical University
  • UMEDA Masahiro
    Department of Medical Informatics, Meiji University of Integrative Medicine
  • FUKUNAGA Masaki
    Biofunctional Imaging Laboratory, Immunology Frontier Research Center, Annex 1F, Graduate School of Frontier Biosciences, Osaka University
  • OGASAWARA Kuniaki
    Department of Neurosurgery, Iwate Medical University
  • YOSHIOKA Yoshichika
    Biofunctional Imaging Laboratory, Immunology Frontier Research Center, Annex 1F, Graduate School of Frontier Biosciences, Osaka University

Bibliographic Information

Other Title
  • Optimized method for culturing outgrowth endothelial progenitor cells

Search this article

Abstract

Purpose: We investigated the spatiotemporal changes in signal in draining lymph nodes of mice to ascertain the size-dependent effects of variously sized particles of iron oxide used to enhance magnetic resonance (MR) lymphography.<br> Materials and Methods: We injected iron oxide particles of 50-, 100-, 200-, or 1,000-nm diameter into the footpads of individual mice and obtained sequential MR images of the popliteal and inguinal lymph nodes with 11.7 tesla up to 6 weeks after particle administration.<br> Results: Up to 30 min after administration of particles smaller than 100 nm, we observed a marked reduction in signal in the popliteal node that spread from the periphery at first observation toward the center of the node in subsequent measurements and persisted up to 6 weeks. In contrast, 1,000-nm particles caused dot-like areas of hypointensity in the popliteal lymph node, primarily in the inner portion, that appeared after 2 days. In the inguinal lymph nodes, signal changes occurred after 2 days for 50- and 100-nm particles and after one week for 1,000-nm particles. For 1,000-nm particles, areas of hypointensity were visible in the inner portion and not the periphery of the inguinal lymph node up to 6 weeks. In this study, we demonstrate the strong dependence of MR imaging contrast in draining lymph nodes on the size of the particle-shaped contrast agents injected subcutaneously. Particle size represented passive and active targeting effects, so micron-sized particles produced delayed enhancement.<br> Conclusion: Choosing the size of iron oxide particles for MR imaging contrast depends on the objective of observation, such as identifying the morphology or migration of immune cells in the lymph node.<br>

Journal

Citations (8)*help

See more

References(74)*help

See more

Related Projects

See more

Details 詳細情報について

Report a problem

Back to top