Self-development of the treatment performance of multi stage vertical flow constructed wetlands working for two years

Bibliographic Information

Other Title
  • 2年目の人工湿地における水質浄化性能の向上
  • 2ネンメ ノ ジンコウ シッチ ニ オケル スイシツ ジョウカ セイノウ ノ コウジョウ

Search this article

Abstract

 Water quality in the multi stage vertical flow constructed wetland treating livestock wastewater was monitored and its treatment performance for two years after start-up was evaluated. Although the performance for the first year was affected by the seasonal variation of water temperature, the treatment capacity during winter season was improved significantly at second year, resulting in robust annual treatment performance of the second year. It suggested that the first year's performance of constructed wetland reflected the adapting process to the regional climate condition and the robust developped performance appeared from second year. Based on the treatment performance obtained for second year, the basic treatment unit for BOD, SS, TKN, T-N and T-P was determined as 26.2g-BOD/m2·d, 21.0g-SS/m2·d, 1.60g-TKN/m2·d, 1.55g-T-N/m2·d and 0.36g-T-P/m2·d, respectively.

Journal

Citations (2)*help

See more

References(4)*help

See more

Related Projects

See more

Details 詳細情報について

Report a problem

Back to top