Patient-mounted Robot for 2D Ultrasound Probe Scanning using McKibben Artificial Muscles

DOI 被引用文献1件 参考文献13件 オープンアクセス
  • Onogi Shinya
    Department of Bio-Applications and Systems Engineering, Tokyo University of Agriculture and Technology
  • Wu Jiawei
    Department of Bio-Applications and Systems Engineering, Tokyo University of Agriculture and Technology
  • Yoshida Toshio
    Department of Bio-Applications and Systems Engineering, Tokyo University of Agriculture and Technology
  • Masuda Kohji
    Department of Bio-Applications and Systems Engineering, Tokyo University of Agriculture and Technology

抄録

In this paper, we describe a robotic ultrasound (US) probe scanning system for reducing the manual tasks of US technicians and assisting in interventional procedures. The system consists of a probe scanning robot that uses McKibben artificial muscles, an optical tracking device, and in-house software for volume reconstruction and automatic guidance of surgical tools. The proposed system is lightweight and safe due to the use of artificial muscles, and allows positional control of the B-scan plane through transformation of US calibration. We applied the robotic system to robotic three-dimensional (3D) ultrasound and automatic ultrasound guidance. To clarify the system's feasibility, we performed phantom and human liver volume reconstructions, as well as needle guidance. The volume qualities of the reconstruction were validated by cross-correlation with reference echograms and reslicing of the reconstructed volumes. The correlation values were 0.80 ± 0.06 for the phantom and 0.53 ± 0.06 for the human liver. Regarding needle guidance, we confirmed that the B-scan plane automatically followed the needle. The translation error was −0.10 ± 1.26 mm and rotation error was −0.22 ± 1.81 degrees. Analysis of frequency response confirmed that the system was able to stably follow a motion at frequencies less than 0.3 Hz. The experimental results demonstrate that the robotic probe scanning system has great potential for yielding acceptable 3D volumes using two-dimensional (2D) ultrasound and assisting interventional procedures under US guidance.

収録刊行物

被引用文献 (1)*注記

もっと見る

参考文献 (13)*注記

もっと見る

関連プロジェクト

もっと見る

詳細情報 詳細情報について

  • CRID
    1390001205502249216
  • NII論文ID
    130005001708
  • DOI
    10.14326/abe.3.130
  • ISSN
    21875219
  • 本文言語コード
    en
  • データソース種別
    • JaLC
    • Crossref
    • CiNii Articles
    • KAKEN
  • 抄録ライセンスフラグ
    使用不可

問題の指摘

ページトップへ