Adsorption of Pb(II) from Aqueous Solution on Oxidized Activated Carbon Fibers

DOI Web Site Web Site 被引用文献3件 オープンアクセス
  • Chensun Shimeng
    Graduate School of Engineering, Chiba University
  • Amano Yoshimasa
    Graduate School of Engineering, Chiba University Safety and Health Organization, Chiba University
  • Machida Motoi
    Graduate School of Engineering, Chiba University Safety and Health Organization, Chiba University
  • Imazeki Fumio
    Safety and Health Organization, Chiba University

この論文をさがす

抄録

Activated carbon fiber (ACF) was oxidized by different concentrations of HNO3 solution and different contact time. Both the original and the oxidized ACFs were tested to adsorb Pb(II) from aqueous solution. Properties of ACFs were characterized by BET surface area, elemental analysis, Boehm titration and the pH of the point of zero charge (pHpzc). The results showed that the maximum adsorption ability of Pb(II) on the oxidized ACF was 0.34 mmol/g at pH 3.0, which was 3 times larger than that on the original ACF, and was enhanced to 0.96 mmol/g by increasing the solution pH from 3.0 to 5.9. The adsorption isotherm of all ACFs obeyed the Langmuir isotherm model. Moreover, the Pb(II) adsorption rate for the oxidized ACF was about 3‐fold faster than that of the original ACF.

収録刊行物

  • 繊維学会誌

    繊維学会誌 71 (5), 180-190, 2015

    社団法人 繊維学会

被引用文献 (3)*注記

もっと見る

関連プロジェクト

もっと見る

キーワード

詳細情報 詳細情報について

問題の指摘