Time-SLIP を用いた心電同期併用法3D True SSFP シーケンスによる骨盤部非造影MRA―移植腎動脈と吻合される右内腸骨動脈の描出評価のための基礎的検討―  [in Japanese] Evaluation of the Right Internal Iliac Artery Which Is Anastomosed to Transplant Renal Artery Using Non-contrast Enhanced MR Angiography with Electrocardiography-gated and 3D True SSFP Time-Spatial Labeling Inversion Pulse Sequence  [in Japanese]

Access this Article

Author(s)

    • 吉田 彩子 Yoshida Ayako
    • 東京女子医科大学病院中央放射線部 Department of Radiological Services, Tokyo Women's Medical University Hospital
    • 白鳥 陽子 Shiratori Yoko
    • 東京女子医科大学病院中央放射線部 Department of Radiological Services, Tokyo Women's Medical University Hospital
    • 鈴木 真 [他] Suzuki Makoto
    • 東京女子医科大学病院中央放射線部 Department of Radiological Services, Tokyo Women's Medical University Hospital
    • 小笹 雅也 Ozasa Masaya
    • 東京女子医科大学病院中央放射線部 Department of Radiological Services, Tokyo Women's Medical University Hospital
    • 竹山 守 Takeyama Mamoru
    • 東京女子医科大学病院中央放射線部 Department of Radiological Services, Tokyo Women's Medical University Hospital
    • 江島 光弘 Eshima Mitsuhiro
    • 東京女子医科大学病院中央放射線部 Department of Radiological Services, Tokyo Women's Medical University Hospital
    • 田嶋 強 Tajima Tsuyoshi
    • 東京女子医科大学病院画像診断・核医学科|現所属:国立国際医療研究センター病院放射線診断科 Department of Diagnostic Imaging & Nuclear Medicine, Tokyo Women's Medical University Hospital|Current affiliation: Radiological Diagnostics, National Center for Global Health and Medicine

Abstract

To evaluate whether electrocardiography-gated is useful in non-contrast-enhanced MRA with time-spatial labeling inversion pulse (Time-SLIP) in renal transplantation patients compared with respiration-triggered free-breathing. Simulation-based analyses of black blood time interval (BBTI) values for spatial selective inversion-recovery pulse and electrocardiography rates were performed, and confirmed on human subjects using a three-dimensional (3D) coherent steady-state free precession (SSFP) sequence on a 1.5 tesla Toshiba MRI scanner. Signal acquisition interval and BBTI values in which signal of a water tissue becomes the null point showed a strong correlation, and successfully suppressed signals from the background and provided better contrast between the arteries and the background. Because electrocardiography-gated non-contrast MRA does not depend on the respiration interval, providing a contrast stable, it was suggested to be an effective screening tool for evaluation of pelvic arteries.

Journal

  • Japanese Journal of Radiological Technology

    Japanese Journal of Radiological Technology 71(5), 439-445, 2015