書誌事項
- タイトル別名
-
- Non-contact evaluation of spot-welded nugget size based on measuring diffracted Lamb waves by focused air-coupled ultrasound
抄録
Spot-welding is widely used in various fields of industries. Since the size and quality of a welded nugget are closely related to the bonding strength of the weld, its quantitative evaluation is important to improve the reliability of the welded structure. In this work, a nugget sizing method based on measuring Lamb waves diffracted at the nugget boundary of a spot weld is proposed. In this method, the nugget size is estimated from the amplitude distribution of Lamb wave diffracted at the nugget boundary when a pair of air-coupled ultrasonic transducers is being scanned near a spot weld. A pair of focused transducers of center frequency of 0.3 MHz is employed. An imitation specimen is firstly evaluated to verify to the validity of the proposed method. Based on the result, the method is applied to the nugget sizing of three spot welds fabricated with different electric currents. Although the estimated values almost agree with those obtained by a water-immersion ultrasonic method, there are certain discrepancies between them due to structural disorders at the nugget/base material interface.
収録刊行物
-
- 日本機械学会論文集
-
日本機械学会論文集 81 (827), 15-00107-15-00107, 2015
一般社団法人 日本機械学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390282680491969664
-
- NII論文ID
- 130005089696
-
- ISSN
- 21879761
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- Crossref
- CiNii Articles
- KAKEN
-
- 抄録ライセンスフラグ
- 使用不可