First Results of Electron Temperature Measurements with a Multi-Pass Thomson Scattering System in the Tandem Mirror GAMMA 10

抄録

A multi-pass Thomson scattering (TS) system has the advantage of enhancing scattered signals. We constructed a multi-pass TS system modeled on the GAMMA 10 TS system; the new system has a polarization-based configuration with an image relaying system. For the first time, we used the new system to measure electron temperatures in the GAMMA 10 plasma. By using the multi-pass TS system with four passes, the integrated scattering signal was magnified by approximately a factor of three.

収録刊行物

  • Plasma and Fusion Research

    Plasma and Fusion Research 9 (0), 1202126-1202126, 2014

    一般社団法人 プラズマ・核融合学会

被引用文献 (2)*注記