美術館・博物館の資料保護に向けた光曝露量の評価方法―染色布を事例に  [in Japanese] Evaluation Method for Light Exposure Levels for Museum Objects : Textiles Case Study  [in Japanese]

Access this Article

Search this Article

Author(s)

Abstract

Illuminance and exposure time are controlled to avoid rapid deterioration of museum objects. However, it is possible that the effect of harmful ultra-violet rapiation and visible light on objects is evaluated incorrectly by integrated illuminance. In this report, an evaluation method for light exposure levels for museum objects is discussed. Exposure tests of textiles with different light sources were conducted, and the progress of deterioration of the textiles was evaluated with two different light exposure level indexes : integrated illuminance and effective radiant exposure. The results show that effective radiant exposure can be used to evaluate light exposure levels causing damage to textiles more accurately. Furthermore, this paper proposes a new method that corrects illuminance and integrated illuminance. The new method easily improves the precision of evaluating light exposure levels with conventional integrated illuminance.

Journal

  • JOURNAL OF THE ILLUMINATING ENGINEERING INSTITUTE OF JAPAN

    JOURNAL OF THE ILLUMINATING ENGINEERING INSTITUTE OF JAPAN 100(2), 74-81, 2016

    The Illuminating Engineering Institute of Japan

Codes

  • NII Article ID (NAID)
    130005154372
  • NII NACSIS-CAT ID (NCID)
    AN00268860
  • Text Lang
    JPN
  • ISSN
    0019-2341
  • NDL Article ID
    027091885
  • NDL Call No.
    Z16-302
  • Data Source
    NDL  J-STAGE 
Page Top