Measurement of Aluminum Erosion Rate by Cavity Ring-Down Spectroscopy

  • YAMAGUCHI Atsushi
    Department of Advanced Energy Engineering Science, Kyushu University
  • KIBE Atsushi
    Department of Advanced Energy Engineering Science, Kyushu University
  • YAMAMOTO Naoji
    Department of Advanced Energy Engineering Science, Kyushu University
  • MORITA Taichi
    Department of Advanced Energy Engineering Science, Kyushu University
  • NAKASHIMA Hideki
    Department of Advanced Energy Engineering Science, Kyushu University

Abstract

<p>A cavity ring-down spectroscopy method to measure sputter erosion and estimate the lifetime of electric propulsion systems was developed. We measured sputtered aluminum atoms from the acceleration grid of an ion thruster. An external-cavity diode laser was used as the probe laser to measure the aluminum transition line from ground state to upper state, at 394.512 nm (vacuum). The erosion rate of the acceleration grid was estimated to be 259 ± 99 ng/s. </p>

Journal

Citations (1)*help

See more

Related Projects

See more

Details 詳細情報について

Report a problem

Back to top