失敗を可視化する採血トレーナ

DOI HANDLE オープンアクセス

書誌事項

タイトル別名
  • Blood Collection Trainer with Visualization of Failure

抄録

<p>This paper proposes a novel trainer for training of blood collection with an injector, an essential skill in medical and nursing fields. An optical motion capturing system and a projector are employed in the proposed system, in addition to the conventional blood collection trainer. The proposed system guides the injector to ideal position and posture until piercing the surface of the simulator. Then, after piercing, subsurface information including the position and the depth of the tip is indicated. Experimental results with subjects have demonstrated that the feedback provided by the proposed system is useful to improve the skill of the blood collection.</p>

収録刊行物

関連プロジェクト

もっと見る

詳細情報 詳細情報について

  • CRID
    1390282679442078592
  • NII論文ID
    130005701319
  • DOI
    10.18974/tvrsj.22.2_217
  • ISSN
    24239593
    1344011X
  • HANDLE
    2433/267714
  • 本文言語コード
    ja
  • データソース種別
    • JaLC
    • IRDB
    • CiNii Articles
    • KAKEN
  • 抄録ライセンスフラグ
    使用不可

問題の指摘

ページトップへ