A Fundamental Verification of an Elevator Emergency Stop Device with a Magnetorheological Fluid Damper
-
- SATO Shunsuke
- 東京都市大学
-
- KOBAYASHI Naoki
- 東京都市大学
-
- KAWASE Keisuke
- 東京都市大学
-
- NAKAGAWA Toshiko
- 東京都市大学
Bibliographic Information
- Other Title
-
- MR流体ダンパを取り入れた新構成エレベータ非常止め装置の基礎検証
- MR リュウタイ ダンパ オ トリイレタ シン コウセイ エレベータ ヒジョウ ヤメ ソウチ ノ キソ ケンショウ
Search this article
Abstract
<p>High-speed and long-distance elevator systems have a serious issue that a large impact force from an emergency stop device injures the passengers in an elevator cage during the emergency stoppage. Therefore, we focused on the safety of the passengers in an elevator cage and proposed a new emergency stop device that consists of a spring and a magnetorheological fluid damper having the variable damping coefficient by a controlled magnetic field. In this paper, we would like to introduce our test installation that consists of the spring, the magnetorheological fluid damper, sensors, a digital controller with LabVIEW and a linear actuator for simulating the deceleration of the emergency stop device. Additionally, we evaluate the fundamental performances of our proposed device that was measured by using the magnetorheological fluid damper as a passive mode.</p>
Journal
-
- Journal of the Japan Society of Applied Electromagnetics and Mechanics
-
Journal of the Japan Society of Applied Electromagnetics and Mechanics 25 (2), 106-111, 2017
The Japan Society of Applied Electromagnetics and Mechanics
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282680483212928
-
- NII Article ID
- 130005863448
- 40021266614
-
- NII Book ID
- AN10457520
-
- ISSN
- 21879257
- 09194452
-
- NDL BIB ID
- 028386163
-
- Text Lang
- en
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
- KAKEN
-
- Abstract License Flag
- Disallowed