動的粘弾性試験によるガラスの熱粘弾性特性評価  [in Japanese] Evaluation of Thermo-Viscoelastic Property of Glass by Dynamic Mechanical Analysis Using a Thermomechanical Analyzer  [in Japanese]

Access this Article

Search this Article

Author(s)

Abstract

<p>   In this study, a dynamic mechanical analysis (DMA) using a thermomechanical analyzer was applied to determine the thermo-viscoelastic properties (shift factors and a master curve) of a borosilicate glass (IWAKI<sub>TE-32</sub>) under various frequencies and temperatures. It was confirmed that the storage elastic moduli decreased with increasing temperature in 575℃ to 770℃ and decreasing frequency in 0.001 Hz to 0.1 Hz. The shift factors and master curve in the glass sample were derived using datasets of the storage elastic moduli. The shift factors for the glass obtained by DMA test agreed well with those by a static creep test. However, the master curve of relaxation modulus estimated by each test was different. That is, stress relaxation behavior of glass indicates nonlinearity, and it was suggested that the master curves of relaxation moduli are different depending on measurement methods.</p>

Journal

  • Journal of the Japanese Society for Experimental Mechanics

    Journal of the Japanese Society for Experimental Mechanics 17(2), 109-116, 2017

    The Japanese Society for Experimental Mechanics

Codes

  • NII Article ID (NAID)
    130005865213
  • NII NACSIS-CAT ID (NCID)
    AA11822914
  • Text Lang
    JPN
  • ISSN
    1346-4930
  • NDL Article ID
    028406536
  • NDL Call No.
    Z74-C355
  • Data Source
    NDL  J-STAGE 
Page Top