Highly sensitive Raman gain coefficient measurement by detecting spontaneous Raman scattering power for distributed Raman amplification systems

DOI Web Site 参考文献6件 オープンアクセス
  • Masuda Hiroji
    Interdisciplinary Graduate School of Science and Engineering, Shimane University
  • Kitamura Kokoro
    Interdisciplinary Graduate School of Science and Engineering, Shimane University

抄録

<p>We propose a highly sensitive method that can safely measure the Raman gain coefficient spectrum by detecting the spontaneous Raman scattering emitted from the transmission fiber pumped by a single-polarization laser-diode light source in distributed Raman amplification systems. With the proposed method, we have successfully obtained an accurate Raman gain coefficient spectrum with a significantly low pump power of ∼0.35 mW at a small Raman gain of 0.01 dB.</p>