THALES-2 によるフィルターベントシステムの有効性評価  [in Japanese] Effectiveness Evaluation of Filtered Containment Venting System using THALES-2  [in Japanese]

Access this Article

Search this Article

Author(s)

Abstract

Filter vent model for THALES-2 code was developed and the effect of the filter vent system was evaluated with the code. In Japan, the installation of filter venting system to the BWRs was considered after the accident of Fukushima-daiichi, where the total blackout caused by tsunami resulted in the large amount of fission product (FP) release to the environment. In this study, the effect of filter vent system in such a total blackout sequence was evaluated. The amount of fission product release was smaller with the filter venting compared to the case in which the reactor containment failed without depressurization.

Journal

  • Maintenology

    Maintenology 15(4), 79-85, 2018

    Japan Society of Maintenology

Codes

  • NII Article ID (NAID)
    130007396435
  • NII NACSIS-CAT ID (NCID)
    AA1249189X
  • Text Lang
    JPN
  • ISSN
    1348-7795
  • NDL Article ID
    027966334
  • NDL Call No.
    Z74-D29
  • Data Source
    NDL  J-STAGE 
Page Top