超小型蒸気インジェクター開発のための作動条件の検討 Investigation of Operating Conditions for Development of an Ultra-Micro Steam Injector

この論文にアクセスする

この論文をさがす

著者

抄録

<p>A steam injector (SI) works as a passive jet pump and has high heat transfer performance due to direct contact condensation between steam flow and subcooled water jet. The objective of the present study is to clarify heat transfer and flow characteristics of an ultra-micro steam injector (UMSI) with throat diameter of 1.0 mm. To this end, internal flow was visualized by a high-speed video camera. Pressure and temperature were measured with the visualization simultaneously. The main parameters were inlet steam pressure, inlet water flow rate and inlet water temperature. As a result, the formation of the water jet was confirmed. In that case, it was verified that discharged pressure became higher than the inlet pressure. The UMSI was successfully operated by achieving simultaneous maintenance of water jet and boosting pressure. In addition, water cooling capacity and steam heating power were evaluated. The operable region was suggested to exist in the large water cooling capacity condition.</p>

収録刊行物

  • 混相流

    混相流 32(2), 239-246, 2018

    日本混相流学会

各種コード

  • NII論文ID(NAID)
    130007402439
  • NII書誌ID(NCID)
    AN10088286
  • 本文言語コード
    JPN
  • ISSN
    0914-2843
  • NDL 記事登録ID
    029128484
  • NDL 請求記号
    Z14-1324
  • データ提供元
    NDL  J-STAGE 
ページトップへ