False-positive TSH receptor antibody—a pitfall of third-generation TSH receptor antibody measurements in neonates—

  • Wada Michiko
    Department of Endocrinology, Metabolism, and Hypertension, Clinical Research Institute, National Hospital Organization Kyoto Medical Center, Kyoto 612-8555, Japan
  • Kita Makoto
    Department of Pediatrics, National Hospital Organization Kyoto Medical Center, Kyoto 612-8555, Japan
  • Kawasaki Kaoru
    Department of Obstetrics and Gynecology, National Hospital Organization Kyoto Medical Center, Kyoto 612-8555, Japan
  • Kusakabe Toru
    Department of Endocrinology, Metabolism, and Hypertension, Clinical Research Institute, National Hospital Organization Kyoto Medical Center, Kyoto 612-8555, Japan
  • Tagami Tetsuya
    Department of Endocrinology, Metabolism, and Hypertension, Clinical Research Institute, National Hospital Organization Kyoto Medical Center, Kyoto 612-8555, Japan Division of Endocrinology and Metabolism, National Hospital Organization Kyoto Medical Center, Kyoto 612-8555, Japan
  • Satoh-‍Asahara Noriko
    Department of Endocrinology, Metabolism, and Hypertension, Clinical Research Institute, National Hospital Organization Kyoto Medical Center, Kyoto 612-8555, Japan
  • Shimatsu Akira
    Clinical Research Institute, National Hospital Organization Kyoto Medical Center, Kyoto 612-8555, Japan
  • Hashimoto Koshi
    Department of Preemptive Medicine and Metabolism, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo 113-8510, Japan

この論文をさがす

抄録

<p>Maternal Graves’ disease (GD) during pregnancy may influence thyroid function in fetuses. Neonates born to mothers with high serum TSH receptor antibody (TRAb) levels have been reported to develop ‘neonatal GD’. Therefore, evaluations of serum thyroid hormone and TRAb levels in neonates upon birth are crucial for a prompt diagnosis. At delivery, we measured TRAb with third-generation TRAb test using an M22 human monoclonal antibody in neonates by collecting umbilical cord blood in a blood collection tube with lithium-heparin, which provides a whole blood/plasma sample. In recent years, we have encountered positive TRAb levels (more than 2.0 IU/L) in nineteen neonates born to mothers with GD whose thyroid hormone levels were almost within the reference range and serum TRAb levels were less than 10 IU/L. All the neonates with positive TRAb levels did not exhibit thyrotoxicosis. However, when we measured TRAb levels with serum sample in six out of the nineteen cases, their serum TRAb levels were all negative, suggesting a discrepancy of TRAb levels between in lithium-heparin plasma from umbilical cord blood and serum. Moreover, this discrepancy was observed in neonates born to euthyroid mothers, adult active GD patients and healthy volunteers. Since lithium-heparin plasma from umbilical cord blood is widely used in laboratory tests at delivery, we may encounter ‘false-positive’ TRAb, which may, in turn, lead to a misdiagnosis of neonatal GD. This is a pitfall of third-generation TRAb measurements in neonates, particularly at delivery, and needs to be considered by obstetricians and neonatologists.</p>

収録刊行物

  • Endocrine Journal

    Endocrine Journal 65 (5), 587-592, 2018

    一般社団法人 日本内分泌学会

被引用文献 (1)*注記

もっと見る

参考文献 (21)*注記

もっと見る

関連プロジェクト

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ