匂いバイオセンサ応答画像のロックイン計測を用いた匂い識別

  • 祐川 侑司
    東京工業大学 科学技術創成研究院 未来産業技術研究所
  • 中本 高道
    東京工業大学 科学技術創成研究院 未来産業技術研究所

書誌事項

タイトル別名
  • Odor Biosensor System based on Image Lock-in Measurement for Odorant Discrimination
  • ニオイ バイオセンサ オウトウ ガゾウ ノ ロックイン ケイソク オ モチイタ ニオイ シキベツ

この論文をさがす

抄録

<p>There has been so far few odor sensors with an array of the biosensor elements. However, an odor sensor constructed in this fashion is expected to have high performance in terms of the ability to discriminate between odorants. In this study, a parallel lock-in measurement circuit was developed to acquire the fluorescent image of the cells even under an ambient light. Since that circuit can extract only the responses of the cells from the fluorescent image, its output represents a specific pattern corresponding to the odorant. Therefore, principal component analysis was applied to that output in order to confirm the availability of the odorant discrimination by using a fluorescent image. It was found that the output pattern from the developed circuit included information enough to discriminate between at least two types of odorants.</p>

収録刊行物

参考文献 (10)*注記

もっと見る

関連プロジェクト

もっと見る

詳細情報 詳細情報について

問題の指摘