結晶調湿X線回折法と 室温測定の再評価  [in Japanese] Recurrence of room-temperature measurement in macromolecular crystallography under humidity control  [in Japanese]

Access this Article

Author(s)

    • 熊坂 崇 Kumasaka Takashi
    • 高輝度光科学研究センタータンパク質結晶解析推進室 Protein Crystal Analysis Division, Japan Synchrotron Radiation Research Institute
    • 馬場 清喜 Baba Seiki
    • 高輝度光科学研究センタータンパク質結晶解析推進室 Protein Crystal Analysis Division, Japan Synchrotron Radiation Research Institute
    • 河村 高志 Kawamura Takashi
    • 高輝度光科学研究センタータンパク質結晶解析推進室 Protein Crystal Analysis Division, Japan Synchrotron Radiation Research Institute

Abstract

<p>  Protein crystals are generally wet and fragile, thus easily suffer from dehydration and temperature change. To preserve the crystals from such sudden physicochemical conditional changes, we developed a crystal mounting method, humid air and glue coating (HAG) method. This method works well to maintain most protein crystals under both cryogenic and room temperature conditions. Room-temperature measurement has recently advanced in time-resolved analysis by serial femtosecond crystallography (SFX) method using X-ray free electron laser (XFEL) facilities, and emerges dynamical properties of proteins, leading to its recurrence even in synchrotron experiments. Here we show the brief guidance to the method and its application, and discuss the perspective of room-temperature structural analysis in macromolecular crystallography.</p>

Journal

  • Journal of the Japanese Association for Crystal Growth

    Journal of the Japanese Association for Crystal Growth 45(4), n/a, 2019

    The Japanese Association for Crystal Growth

Codes