Comparison between blood coagulability in the intra-atrial and peripheral regions during the acute phase after rapid atrial pacing

  • Yamada Shusaku
    Animal Medical Center, Tokyo University of Agriculture and Technology, 3-5-8 Sawai-cho, Fuchushi, Tokyo 183-8509, Japan
  • Hirao Daiki
    Animal Medical Center, Tokyo University of Agriculture and Technology, 3-5-8 Sawai-cho, Fuchushi, Tokyo 183-8509, Japan
  • Miura Naoki
    Joint Faculty of Veterinary Medicine, Kagoshima University, 1-21-24 Koorimoto, Kagoshima 890-0065, Japan
  • Iwanaga Tomoko
    Joint Faculty of Veterinary Medicine, Kagoshima University, 1-21-24 Koorimoto, Kagoshima 890-0065, Japan
  • Kawaguchi Takae
    Animal Medical Center, Tokyo University of Agriculture and Technology, 3-5-8 Sawai-cho, Fuchushi, Tokyo 183-8509, Japan
  • Yoshimura Aritada
    Animal Medical Center, Tokyo University of Agriculture and Technology, 3-5-8 Sawai-cho, Fuchushi, Tokyo 183-8509, Japan
  • Oomori Takahiro
    Animal Medical Center, Tokyo University of Agriculture and Technology, 3-5-8 Sawai-cho, Fuchushi, Tokyo 183-8509, Japan
  • Nagasato Tomoka
    Department of System Biology in Thromboregulation, Graduate School of Medical and Dental Sciences, Kagoshima University, 8-35-1 Sakuragaoka, Kagoshima 890-8544, Japan
  • Maruyama Ikuro
    Department of System Biology in Thromboregulation, Graduate School of Medical and Dental Sciences, Kagoshima University, 8-35-1 Sakuragaoka, Kagoshima 890-8544, Japan
  • Fukushima Ryuji
    Animal Medical Center, Tokyo University of Agriculture and Technology, 3-5-8 Sawai-cho, Fuchushi, Tokyo 183-8509, Japan

この論文をさがす

抄録

<p>The changes in intra-atrial blood coagulability of acute phase after development of atrial fibrillation (AF) have not been elucidated in human. In the present study, blood coagulability were examined in the intra-atrial and peripheral regions during the acute phase after development of rapid atrial pacing (RAP) in experimentally created model dog similar to AF, using Total Thrombus-formation Analysis System (T-TAS) that is capable of comprehensively evaluating thrombogenicity in the bloodstream in the microvascular channel. According to the results, both the coagulating function-evaluating time to +10 kPa (T10) and occlusion time (OT) of the AR chip (chip for thrombus analysis mixed with coagulation and platelet) were significantly shortened in the atrial blood as early as 30 min after pacing (T10, 150.5 ± 40.5 s; OT, 212.4 ± 44.3 s) compared to the pre-pacing levels (T10, 194.5 ± 47.5 s; OT, 259.9 ± 49.5 s) (P<0.05). The OT of PL chip (chip for platelet thrombus analysis) was significantly shortened 30 min after pacing (231.8 ± 57.6 s), compared to the pre-pacing level (289.5 ± 96.0 s) (P<0.05). Meanwhile, none of T10 and OT of AR and PL chips showed any significant changes in the peripheral blood. The study demonstrated increase of blood coagulability 30 min after development of RAP. While no significant changes were observed in the peripheral blood in the present study, the outcome suggested that the anti-thrombus treatments are better to be started early after AF even if coagulability of the peripheral blood shows no change.</p>

収録刊行物

  • Experimental Animals

    Experimental Animals 68 (2), 137-146, 2019

    公益社団法人 日本実験動物学会

被引用文献 (1)*注記

もっと見る

参考文献 (39)*注記

もっと見る

関連プロジェクト

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ