Effect of light-curing time on light-cure/post-cure volumetric polymerization shrinkage and regional ultimate tensile strength at different depths of bulk-fill resin composites

  • IDE Kurumi
    Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
  • NAKAJIMA Masatoshi
    Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
  • HAYASHI Juri
    Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
  • HOSAKA Keiichi
    Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
  • IKEDA Masaomi
    Department of Oral Prosthetic Engineering, Graduate School, Faculty of Dentistry, Tokyo Medical and Dental University (TMDU)
  • SHIMADA Yasushi
    Department of Operative Dentistry, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
  • FOXTON Richard M.
    Division of Conservative Dentistry, King’s College London Dental Institute at Guy’s, King’s and St Thomas’ Hospitals, King’s College London
  • SUMI Yasunori
    National Center for Geriatrics oand Gerontology, Department of Advanced Dental Research, Center of Advanced Medicine for Dental and Oral Disease
  • TAGAMI Junji
    Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU) Global Center of Excellence Program; International Research Center for Molecular Science in Tooth and Bone Diseases, Tokyo Medical and Dental University

Abstract

<p>The aim of this study was to investigate volumetric polymerization shrinkage (VS), using swept-source optical coherence tomography (SS-OCT), of bulk-fill composites with different light-curing strategies; immediately after light-irradiation and after 24 h, and to evaluate their regional ultimate tensile strength (UTS) at different curing depths. The immediate VS after photo-polymerization decreased when the curing light-curing time was reduced from 20 to 10 to 5 s. On the other hand, their VS values after 24 h significantly increased due to the post-cure polymerization, resulting in similar VS values at all the light-curing times. Five seconds light-curing decreased the regional UTS of resin composites after the 24 h period compared with the 10 and 20 s light-curing regimes; therefore, the remarkable progress of post-cure polymerization after light-curing for a short time would not lead to an improvement in the mechanical properties of resin composites. The influence of the light-curing time on the curing depth was dependent upon the bulk-fill composite material.</p>

Journal

  • Dental Materials Journal

    Dental Materials Journal 38 (4), 621-629, 2019-07-26

    The Japanese Society for Dental Materials and Devices

Citations (2)*help

See more

References(44)*help

See more

Related Projects

See more

Details 詳細情報について

Report a problem