Evaluation of an Energetic Particle Profile Using a Tangential-FIDA Diagnostic in the Large Helical Device
-
- FUJIWARA Yutaka
- National Institute for Fusion Science, National Institutes of Natural Sciences
-
- KAMIO Shuji
- National Institute for Fusion Science, National Institutes of Natural Sciences
-
- YAMAGUCHI Hiroyuki
- National Institute for Fusion Science, National Institutes of Natural Sciences
-
- GARCIA Alvin V.
- University of California, Irvine
-
- STAGNER Luke
- Oak Ridge Institute for Science and Education
-
- NUGA Hideo
- National Institute for Fusion Science, National Institutes of Natural Sciences
-
- SEKI Ryosuke
- National Institute for Fusion Science, National Institutes of Natural Sciences SOKENDAI (The Graduate University for Advanced Studies)
-
- OGAWA Kunihiro
- National Institute for Fusion Science, National Institutes of Natural Sciences SOKENDAI (The Graduate University for Advanced Studies)
-
- ISOBE Mitsutaka
- National Institute for Fusion Science, National Institutes of Natural Sciences SOKENDAI (The Graduate University for Advanced Studies)
-
- YOKOYAMA Masayuki
- National Institute for Fusion Science, National Institutes of Natural Sciences SOKENDAI (The Graduate University for Advanced Studies)
-
- NISHITANI Takeo
- National Institute for Fusion Science, National Institutes of Natural Sciences
-
- HEIDBRINK William W.
- National Institute for Fusion Science, National Institutes of Natural Sciences University of California, Irvine
-
- OSAKABE Masaki
- National Institute for Fusion Science, National Institutes of Natural Sciences SOKENDAI (The Graduate University for Advanced Studies)
-
- LHD Experiment Group
- National Institute for Fusion Science, National Institutes of Natural Sciences
この論文をさがす
抄録
<p>A tangential Fast-Ion D Alpha (FIDA) diagnostic is applied to the Large Helical Device (LHD) in order to observe energetic distribution of toroidal circulating energetic particles which are produced by tangential Negative Neutral Beams (NNB). A perpendicular Positive NB (PNB) is used as the diagnostic probe beam of the tangential-FIDA diagnostic in this observation geometry. In order to assess the appropriateness of the tangential-FIDA diagnostic, the experimental result was compared with a Silicon-diode-based Fast Neutral Analyzer (Si-FNA) which was installed on the same line of sight. As a result of the comparison, the tangential-FIDA and the Si-FNA experimental data obtained good linearity in the energy region from 60 keV to 180 keV. In addition, an enhanced FIDASIM was applied for analyzing the FIDA on the three-dimensional magnetic configuration fusion device.</p>
収録刊行物
-
- Plasma and Fusion Research
-
Plasma and Fusion Research 14 (0), 3402129-3402129, 2019-07-11