書誌事項
- タイトル別名
-
- Investigation of Characteristics of Human’s Warm Sensation Heated by Visible Light LEDs
抄録
<p>Investigation of human thermal perception concerning a thermal display is important for designing a better interface. However, research about human perception characteristics for a thermal display using radiant heat has not been conducted so much. In this study, we examined human thermal perception when the palm was irradiated by visible light. Firstly, we compared temperature distribution in case of a peltier device and the visible light LEDs. The result showed that the temperature distribution of the LEDs was ununiform. Secondly, we revealed the minimum temperature where a human can feel the warmth on the skin. As a result, the required minimum temperature of the visible light LEDs to feel warmth is higher than that of a contact type thermal display. The result indicates that the difference between deep body temperature and skin temperature became small and that influences human thermal perception since visible light is absorbed into melanin and hemoglobin well.</p>
収録刊行物
-
- ロボティクス・メカトロニクス講演会講演概要集
-
ロボティクス・メカトロニクス講演会講演概要集 2019 (0), 2P1-O05-, 2019
一般社団法人 日本機械学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390846609786640256
-
- NII論文ID
- 130007775085
-
- ISSN
- 24243124
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可