STUDY ON APPLICATION OF SIMPLE DUST SENSOR TO TUNNEL CONSTRUCTION SITE
-
- KAKEYA Koshiro
- 山口大学大学院 創成科学研究科
-
- HAYASHI Hisashi
- 山口大学大学院 創成科学研究科
-
- OTSUKA Teruhito
- (独)労働者健康安全機構 労働安全衛生総合研究所
-
- NAKAMURA Kenji
- (独)労働者健康安全機構 労働安全衛生総合研究所
-
- SHINJI Masato
- 山口大学大学院 創成科学研究科
Bibliographic Information
- Other Title
-
- 簡易粉じん測定器のトンネル建設現場への適用に関する研究
Abstract
<p> In order to design a suitable tunnel ventilation method among various ventilation methods in the tunnel construction site, conducting multi-point and frequent measurement of floating dust concentration and aiming to collect simply the location of dust in the tunnel by cheap and small dust sensor in this study. I have developed a simplified tunnel dust sensor by an improvement the light scattering dust concentration sensor developed for general household air purifiers. And, It was clear by simulated tunnel environmental experiments whether the developed dust sensor is suitable for measurement in a tunnel. As a result, it was found that the developed simplified tunnel dust sensor can measure the concentration generated during tunnel construction. In addition, it was also clear that the measurement results are almost the same as the digital dust sensor used for dust measurement in tunnel construction sites.</p>
Journal
-
- Journal of Japan Society of Civil Engineers, Ser. F1 (Tunnel Engineering)
-
Journal of Japan Society of Civil Engineers, Ser. F1 (Tunnel Engineering) 75 (2), I_12-I_19, 2019
Japan Society of Civil Engineers
- Tweet
Details 詳細情報について
-
- CRID
- 1390002184882271488
-
- NII Article ID
- 130007809336
-
- ISSN
- 21856575
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
- KAKEN
-
- Abstract License Flag
- Disallowed