FULL SCALE LOADING TEST UP TO LARGE STORY DRIFT ON EXTERIOR WALL OF ALC PANEL WITH WINDOW AND DOOR ATTACHED TO STEEL MOMENT FRAME

Bibliographic Information

Other Title
  • 鉄骨骨組に取り付けた窓と扉を含むALC 外壁の大変形時まで再現した実大載荷実験

Search this article

Abstract

<p>Full scale loading test up to large story drift on Exterior Wall of ALC panel with window and door attached to steel moment frame was conducted. No damage was observed on the surface without openings except for the bottom of the panel. On the surface with openings, many damages such as cracks in the panel and breaks in the welding of the substrate were observed especially at large story drift angle of 1/50 or more. In addition, degrading of the openablility of the window and door according to residual story drift angle were examined.</p>