Characteristics of Electrolytic Deoxygenation Devices Using SiC and SWCNT Electrodes

  • Keiichi Kaneto
    Faculty of Engineering, Osaka Institute of Technology, 5-16-1 Ohmiya, Asahi-ku, Osaka 535-8585 , Japan
  • Sadahito Uto
    Faculty of Engineering, Osaka Institute of Technology, 5-16-1 Ohmiya, Asahi-ku, Osaka 535-8585 , Japan

抄録

<jats:title>Abstract</jats:title> <jats:p>Electrolytic deoxygenation devices have been fabricated using SiC, SWCNT, graphene, and PEDOT*PSS for the electrodes. Characteristics of devices were studied by measuring currents, O2 and H2 concentrations, and humidity during deoxygenation in a closed container. Performances of the devices being composed of cation or anion exchange membrane are discussed comparing with the standard catalyst of Pt-black. It is found that generation of moisture and H2 was substantially involved in the deoxygenation.</jats:p>

収録刊行物

  • Chemistry Letters

    Chemistry Letters 50 (2), 342-345, 2021-02

    Oxford University Press (OUP)

被引用文献 (1)*注記

もっと見る

参考文献 (22)*注記

もっと見る

関連プロジェクト

もっと見る

キーワード

詳細情報 詳細情報について

問題の指摘