温湿度を変えた環境下のESD試験器の気中放電に対する放電電流ピークの絶縁破壊電位傾度依存性とその計算

書誌事項

タイトル別名
  • Dependence and Its Calculation on Breakdown Potential Gradients of Air Discharge Current Peaks from ESD Generator in Environment with Different Temperature and Humidity

抄録

<p>The air discharge currents from an ESD generator were measured at charging voltages from 2 kV to 15 kV in an environment with different temperature and humidity. Dependence of the current peaks on breakdown potential gradients in addition to spark lengths is shown, and is calculated using a simplified equivalent circuit based on the IEC standard for the ESD generator.</p>

収録刊行物

被引用文献 (1)*注記

もっと見る