Effect of Negative Ions on Decomposition of Acetic Acid in Water using DC Corona Discharge

Bibliographic Information

Other Title
  • 直流コロナ放電を用いた酢酸の分解における負イオンの影響
  • チョクリュウ コロナ ホウデン オ モチイタ サクサン ノ ブンカイ ニ オケル フイオン ノ エイキョウ

Search this article

Abstract

<p>This study investigates the characteristics of acetic acid decomposition on a negative DC corona discharge over water. The corona discharge is 4 mm away from the water surface. Furthermore, this study explores the mechanisms involved in the chemical reactions of active species during water treatment, using discharged plasma. During processing, oxygen or ozone is supplied to the reactor. The results of experiment and simulation show the same trend on time variation of acetic acid concentration. Therefore, the simulation model that considers the supply of ozone, hydrogen peroxide and O3- can confirm the change in acetic acid concentration. Our results indicate that negative ions such as O3- can be used for water treatment by DC corona discharge.</p>

Journal

References(2)*help

See more

Related Projects

See more

Details 詳細情報について

Report a problem

Back to top