Temperature Measurement of HEK-X Expansion Tube Flow by Laser Absorption Spectroscopy

Abstract

<p>An expansion tube is a promising facility to simulate atmospheric entry conditions, although its flow conditions have not been completely characterized mainly owing to its short operation time. In this study, laser absorption spectroscopy was applied to diagnose HEK-X expansion tube flow in the Kakuda Space Center. The target is an absorption line of an oxygen molecule at 763 nm. To increase the sensitivity, optical path length was extended by five times using mirrors. Consequently, an absorption profile with a fractional absorption of 2.4 ± 0.3% was detected at a shock velocity of 7.65 ± 0.05 km/s. The estimated translational temperature from the Voigt fitting was 2750 ± 450 K.</p>