Research on city gas distribution system : characteristic analysis for gas pressure regulator and development of load simulator 都市ガス供給システムに関する研究 : ガス整圧器の特性解析及び負荷シミュレータの開発

Search this Article

Author

    • 潘, 衛民 パン, エイミン

Bibliographic Information

Title

Research on city gas distribution system : characteristic analysis for gas pressure regulator and development of load simulator

Other Title

都市ガス供給システムに関する研究 : ガス整圧器の特性解析及び負荷シミュレータの開発

Author

潘, 衛民

Author(Another name)

パン, エイミン

University

東京工業大学

Types of degree

博士 (工学)

Grant ID

甲第3440号

Degree year

1997-03-26

Note and Description

博士論文

Table of Contents

  1. 論文目録 / (0002.jp2)
  2. 要旨 / (0005.jp2)
  3. Contents / p1 (0007.jp2)
  4. 1.Introduction / p1 (0009.jp2)
  5. 1.1 Gas Distribution System and Gas Pressure Regulator / p1 (0009.jp2)
  6. 1.2 Background / p2 (0010.jp2)
  7. 1.3 Purpose of research / p3 (0011.jp2)
  8. 1.4 Main Contents / p3 (0011.jp2)
  9. Nomenclature / p5 (0013.jp2)
  10. 2.Gas Distribution System--Configuration and Operation Principle / p8 (0016.jp2)
  11. 2.1 City Gas Distribution / p8 (0016.jp2)
  12. 2.2 Gas Pressure Regulator / p13 (0021.jp2)
  13. 2.3 Test Facility for Gas Pressure Regulator / p22 (0030.jp2)
  14. 2.4 Characteristics of City Gas / p24 (0032.jp2)
  15. 3.Characteristics Analysis of Gas Pressure Regulator / p26 (0034.jp2)
  16. 3.1 Mathematical Model / p26 (0034.jp2)
  17. 3.2 Experiments / p37 (0045.jp2)
  18. 3.3 Characteristics of Pilot Valve / p52 (0060.jp2)
  19. 3.4 Characteristic Analysis of Gas Pressure Regulator / p58 (0066.jp2)
  20. 3.5 Conclusions / p69 (0077.jp2)
  21. 4.Gas Distribution System Simulation / p70 (0078.jp2)
  22. 4.1 Numerical Solution for Gas Flow in a Pipe / p71 (0079.jp2)
  23. 4.2 Gas Distribution System Simulation / p81 (0089.jp2)
  24. 4.3 Observations / p102 (0110.jp2)
  25. 4.4 Conclusions / p113 (0121.jp2)
  26. 5.Load Simulator for Behavior Evaluation of Gas Pressure Regulator / p114 (0122.jp2)
  27. 5.1 Principle of Load Simulator / p115 (0123.jp2)
  28. 5.2 Composition of Load Simulator / p116 (0124.jp2)
  29. 5.3 Simulator for Pilot Valve / p119 (0127.jp2)
  30. 5.4 Experiments / p121 (0129.jp2)
  31. 5.5 Influence of Using Compressed Air / p130 (0138.jp2)
  32. 5.6 Conclusions / p131 (0139.jp2)
  33. 6.Conclusions / p132 (0140.jp2)
  34. Acknowledgment / p133 (0141.jp2)
  35. References / p134 (0142.jp2)