Studies of millimeter-wave imaging array for the GAMMA10 tandem mirror ガンマ10タンデムミラーにおけるミリ波イメージングアレイの研究
Access this Article
Search this Article
Author
Bibliographic Information
- Title
-
Studies of millimeter-wave imaging array for the GAMMA10 tandem mirror
- Other Title
-
ガンマ10タンデムミラーにおけるミリ波イメージングアレイの研究
- Author
-
大山, 直幸
- Author(Another name)
-
オオヤマ, ナオユキ
- University
-
筑波大学
- Types of degree
-
博士 (理学)
- Grant ID
-
甲第2064号
- Degree year
-
1999-03-25
Note and Description
博士論文
1998
Table of Contents
- Contents / p3 (0004.jp2)
- Abstract / p1 (0003.jp2)
- Contents / p3 (0004.jp2)
- 1. Introduction1 / p1 (0006.jp2)
- 1.1 Millimeter-Wave Imaging Diagnostics / p3 (0007.jp2)
- 1.2 Organization of the Thesis / p5 (0008.jp2)
- 2. Principles of Millimeter-Wave Imaging / p7 (0009.jp2)
- 2.1 Propagation of Electromagnetic Waves in a Magnetized Plasma / p8 (0010.jp2)
- 2.2 Interferometry / p13 (0012.jp2)
- 2.3 Abel Inversion Technique / p15 (0013.jp2)
- 2.4 Electron Cyclotron Emission Radiometry / p16 (0014.jp2)
- 2.5 Millimeter-Wave Imaging Diagnostics / p20 (0016.jp2)
- 3. Description of the GAMMA10 Device / p23 (0017.jp2)
- 3.1 Overview of the GAMMA10 Tandem Mirror / p23 (0017.jp2)
- 3.2 Heating Systems / p26 (0019.jp2)
- 3.3 Diagnostics / p28 (0020.jp2)
- 4. Millimeter-Wave Imaging Array System / p33 (0022.jp2)
- 4.1 Overview of the Imaging System / p34 (0023.jp2)
- 4.2 Two-Dimensional Detector Array / p35 (0023.jp2)
- 4.3 Optical System / p37 (0024.jp2)
- 4.4 Phase Detection System / p43 (0027.jp2)
- 4.5 ECE Heterodyne Radiometer System / p44 (0028.jp2)
- 4.6 Simulation Experiment of the Imaging Array System / p46 (0029.jp2)
- 5. Development of Monolithic Microwave Integrated Circuit Detector / p48 (0030.jp2)
- 5.1 Design of the MMIC Detector / p48 (0030.jp2)
- 5.2 Characteristics of the MMIC Detector / p50 (0031.jp2)
- 5.3 Application of the MMIC Detector to ECE Measurement / p52 (0032.jp2)
- 6. Experimental Results of the Imaging Array System / p56 (0034.jp2)
- 6.1 Density Profile Measurements / p56 (0034.jp2)
- 6.2 ECE Measurements / p62 (0037.jp2)
- 6.3 Fluctuation Measurements / p69 (0040.jp2)
- 6.4 Discussion / p79 (0045.jp2)
- 7. Density Profiles and Confinement in GAMMA10 / p87 (0049.jp2)
- 7.1 Axial Density Profiles of a Tandem Mirror Plasma / p87 (0049.jp2)
- 7.2 Confining Potential Effect on Plasma Density Profile / p94 (0053.jp2)
- 7.3 Discussion / p99 (0055.jp2)
- 8. Conclusions / p102 (0057.jp2)
- Acknowledgments / p104 (0058.jp2)
- References / p106 (0059.jp2)
- Appendix / p110 (0061.jp2)