Electrochemical sensors in immunological analysis
Author(s)
Bibliographic Information
Electrochemical sensors in immunological analysis
Plenum Press, c1987
Available at 7 libraries
  Aomori
  Iwate
  Miyagi
  Akita
  Yamagata
  Fukushima
  Ibaraki
  Tochigi
  Gunma
  Saitama
  Chiba
  Tokyo
  Kanagawa
  Niigata
  Toyama
  Ishikawa
  Fukui
  Yamanashi
  Nagano
  Gifu
  Shizuoka
  Aichi
  Mie
  Shiga
  Kyoto
  Osaka
  Hyogo
  Nara
  Wakayama
  Tottori
  Shimane
  Okayama
  Hiroshima
  Yamaguchi
  Tokushima
  Kagawa
  Ehime
  Kochi
  Fukuoka
  Saga
  Nagasaki
  Kumamoto
  Oita
  Miyazaki
  Kagoshima
  Okinawa
  Korea
  China
  Thailand
  United Kingdom
  Germany
  Switzerland
  France
  Belgium
  Netherlands
  Sweden
  Norway
  United States of America
Note
Includes bibliographies and index
Description and Table of Contents
Description
The development of radioimmunoassay (RIA) by R.S. Yalow and S.A. Berson in 1959 opens up a new avenue in ultra sensitive analysis of trace substances in complex biological systems. In recognition of the enormous contributions of RIA to basic research in biology and to routine clinical tests in laboratory medicine, R.S. Yalow, the co-developer of RIA, was awarded, in 1977, the Nobel Prize for Medicine and Physiology. The basic principle of RIA is elegantly simple. It is based on a specific, competitive binding reaction between the analyte and the radio-labeled analog of the analyte for the specific antibody raised to the analyte. The combination of high specificity and affinity of an antibody molecule makes it a very versatile analytical reagent capable of reacting specifically with analytes at a very low concentration in a complex solution such as serum. The sensitivity of RIA is provided by using a radioactive tracer.
Table of Contents
On the Direct Immunochemical Potentiometric Signal.- Selective Antibody Responsive Membrane Electrodes.- Electroimmunoassay of PGE2: An Antibody-Sensitive Electrode Based Competive Protein-Binding Assay.- Immuno-Potentiometric Sensors with Antigen Coated Membrane.- The Opsonized Electrode.- Homogeneous Voltammetric Immunoassay of Haptens.- Immunoassay by Differential Pulse Polarography and Anodic Stripping Voltammetry.- Separation-Free (Homogeneous) Amperometric Immunoassay Using an Apoenzyme as the Label.- Digoxin Homogeneous Enzyme Immunoassay with Amperometric Detection.- Antibody to an Enzyme as the Modulator in Separation-Free Enzyme Immunoassays with Electrochemical Sensor.- Immunochemical Determination of Creatine Kinase Isoenzyme-MB.- Immunosensor Based on Labeled Liposome Entrapped-Enzymes.- Measurement of Complement Fixation with Ion Selective Membrane Electrodes.- Antibody-Antigen Precipitin Reaction Monitoring with an Ion Selective Electrode.- Enzyme-Linked Immunoassay with a Fluoride Ion Selective Electrode.- Heterogeneous Potentiometric Enzyme Immunoassay for Antigens and Haptens with Iodide Selective Electrode.- Enzyme Immunoassay using the Ammonia Gas-Sensing Electrode.- Homogeneous and Heterogeneous Enzyme Immunoassays Monitored with Carbon Dioxide Sensing Membrane Electrode.- Enzyme-Linked Immunosorbent Assays Using Oxygen-Sensing Electrode.- Bioaffinity Electrochemical Sensor with Preformed Metastable Ligand-Receptor Complex.- Electric Pulse Accelerated Immunoassay.- Heterogeneous Enzyme Immunoassay with Amperometric Detection.- Enzyme Immunoassay in Flow Systems with Electrochemical and Other Detectors.- Use of Immunochemical Separation and Electrochemical Detection in Flow Injection Analysis of Lactic Dehydrogenase.- Rapid Subpicomole Enzyme Immunoassay by Flow Injection with Amperometric Detection.- Contributors.
by "Nielsen BookData"