Diagnostic biosensor polymers : developed from a symposium sponsored by the Division of Industrial and Engineering Chemistry, Inc., at the 205th National Meeting of the American Chemical Society, Denver, Colorado, March 28-April 2, 1993
Author(s)
Bibliographic Information
Diagnostic biosensor polymers : developed from a symposium sponsored by the Division of Industrial and Engineering Chemistry, Inc., at the 205th National Meeting of the American Chemical Society, Denver, Colorado, March 28-April 2, 1993
(ACS symposium series, 556)
American Chemical Society, 1994
Available at 6 libraries
  Aomori
  Iwate
  Miyagi
  Akita
  Yamagata
  Fukushima
  Ibaraki
  Tochigi
  Gunma
  Saitama
  Chiba
  Tokyo
  Kanagawa
  Niigata
  Toyama
  Ishikawa
  Fukui
  Yamanashi
  Nagano
  Gifu
  Shizuoka
  Aichi
  Mie
  Shiga
  Kyoto
  Osaka
  Hyogo
  Nara
  Wakayama
  Tottori
  Shimane
  Okayama
  Hiroshima
  Yamaguchi
  Tokushima
  Kagawa
  Ehime
  Kochi
  Fukuoka
  Saga
  Nagasaki
  Kumamoto
  Oita
  Miyazaki
  Kagoshima
  Okinawa
  Korea
  China
  Thailand
  United Kingdom
  Germany
  Switzerland
  France
  Belgium
  Netherlands
  Sweden
  Norway
  United States of America
Note
Includes bibliographical references and indexes
Description and Table of Contents
Description
This volume was developed from a symposium sponsored by the Division of Industrial and Engineering Chemistry Inc, at the 205th National Meeting of the American Chemical Society held in Denver, Colorado, March 28-April 2, 1993. Reviewing the latest advances in redox/conductive polymers and membranes, this book describes new redox polymers useful in miniaturizing biosensors, and examines polymers for optical biosensors. It investigates interesting membranes to enhance the performance of biosensors, features biocompatible polymers useful in implantable sensors, and includes discussions on enzyme immobilization and methods to increase enzyme stability. The book also describes the chemistry and technology of dry chemistries.
Table of Contents
- Part 1 Biosensers: diagnostic polymers and coatings - chemistry, technology and applications, Arthur M. Usmani
- fiber-optic sensors based on degradable polymers, Venetka Agayn and David R. Walt
- enhancement of the stability of wired quinoprotein glucose dehydrogenase electrode, Ling Ye et al
- amperometric glucose-sensing electrodes with the use of modified enzymes, F. Mizutani et al
- electron-transport rates in an enzyme electrode for glucose, Nigel A. Surridge et al
- sandwich-type amperometric enzyme electrodes for determination of glucose, S. Mutlu et al
- reproducible electrodeposition technique for immobilizing glucose oxidase and a differentially permeable outer-membrane material for use on a miniature implantable glucose sensor, K.W. Johnson et al
- thin-layer flow-through enzyme immunosensor based on polycaprolactam net, Lizhi Yin et al. Part 2 Biosensor polymers and membranes: conducting polymers and their application in amperometric biosensors, Wolfgang Schuhmann
- poly(ether amine quinone)s as electron-transfer relay systems in amperometric glucose sensors, Hsing Lin Lan et al
- flow-injection analysis of some anionic species - automated, miniaturized, dual-working electrode potentiostat using a poly(3-methylthiophene)-modified electrode, Elmo A. Blubaugh et al
- characterization of stability of modified poly(vinyl chloride) membranes for microfabricated ion-selective electrode arrays in biomedical applications, Ernoe Lindner et al
- biosensors based on ultrathin film composite membranes, Charles R. Martin et al
- viologen derivative containing polysiloxane as an electron-transfer mediator in amperometric glucose sensors, Hirokio I. Karan et al
- hydrogen peroxide electrodes based on electrical connection of redox centres of various peroxidases to electrodes through a three-dimensional electron-relaying polymer network, Mark S. Vreeke and Adam Heller. Part 3 Biocompatibility and biomimetics. Part 4 Immobilization and stabilization methods. (Part contents)
by "Nielsen BookData"