Practical inductively coupled plasma spectroscopy
Author(s)
Bibliographic Information
Practical inductively coupled plasma spectroscopy
(Analytical Techniques in the Sciences(AnTS))
Wiley, c2005
- : hardback
- pbk. : alk. paper
Available at 8 libraries
  Aomori
  Iwate
  Miyagi
  Akita
  Yamagata
  Fukushima
  Ibaraki
  Tochigi
  Gunma
  Saitama
  Chiba
  Tokyo
  Kanagawa
  Niigata
  Toyama
  Ishikawa
  Fukui
  Yamanashi
  Nagano
  Gifu
  Shizuoka
  Aichi
  Mie
  Shiga
  Kyoto
  Osaka
  Hyogo
  Nara
  Wakayama
  Tottori
  Shimane
  Okayama
  Hiroshima
  Yamaguchi
  Tokushima
  Kagawa
  Ehime
  Kochi
  Fukuoka
  Saga
  Nagasaki
  Kumamoto
  Oita
  Miyazaki
  Kagoshima
  Okinawa
  Korea
  China
  Thailand
  United Kingdom
  Germany
  Switzerland
  France
  Belgium
  Netherlands
  Sweden
  Norway
  United States of America
Note
Includes bibliographical references and index
Description and Table of Contents
- Volume
-
: hardback ISBN 9780470093481
Description
The book provides an up-to-date account of inductively coupled plasmas and their use in atomic emission spectroscopy and mass spectrometry. Specific applications of the use of these techniques are highlighted including applications in environmental, food and industrial analysis. It is written in a distance learning / open learning style; suitable for self study applications. It contains contain self-assessment and discussion questions, worked examples and case studies that allow the reader to test their understanding of the presented material.
Table of Contents
Series Preface. Preface. Acknowledgements. Acronyms, Abbreviations and Symbols. About the Author. 1 Methodology for Trace Elemental Analysis. 1.1 Introduction. 1.2 Analytical Terms and their Definitions. 1.3 Units. 1.4 Calibration Strategies. 1.5 Presentation of Data: Tables. 1.6 Presentation of Data: Graphs. 1.7 Calculations: Dilution Factors. 1.8 Quality Assurance and the Use of Certified Reference Materials. 2 Sample Preparation for Inductively Coupled Plasma Spectroscopy. 2.1 Introduction. 2.2 Aqueous Samples. 2.3 Solid Samples. 2.3.1 Decomposition Techniques. 2.4 Extraction Procedures. References. 3 Sample Introduction Procedures for Inductively Coupled Plasmas. 3.1 Introduction. 3.2 Nebulizers. 3.3 Spray Chambers and Desolvation Systems. 3.4 Discrete Sample Introduction. 3.5 Continuous Sample Introduction. 3.6 Hydride and Cold Vapour Techniques. References. 4 The Inductively Coupled Plasma and Other Sources. 4.1 Introduction. 4.2 Inductively Coupled Plasma. 4.3 Direct-Current Plasma. 4.4 Microwave-Induced Plasma. 4.5 Glow Discharge. References. 5 Inductively Coupled Plasma-Atomic Emission Spectroscopy. 5.1 Fundamentals of Spectroscopy. 5.2 Plasma Spectroscopy. 5.3 Spectrometers. 5.4 Detectors. 5.5 Interferences. References. 6 Inductively Coupled Plasma-Mass Spectrometry. 6.1 Fundamentals of Mass Spectrometry. 6.2 Inorganic Mass Spectrometry. 6.2.1 Ion Source: ICP. 6.3 Interface. 6.4 Mass Spectrometer. 6.5 Detectors. 6.6 Interferences. 6.7 Isotope Dilution Analysis. 6.8 Mass Spectral Interpretation. References. 7 Selected Applications of Inductively Coupled Plasma Technology. 7.1 Forensic Science: Document Analysis. 7.2 Industrial Analysis: Coal. 7.3 Clinical/Biological Analysis: Whole Blood and Urine. 7.4 Materials Analysis: Gadolinium Oxide. 7.5 Environmental Analysis: Soil. 7.6 Food Analysis: Milk Products. 7.7 Pharmaceutical Analysis. References. 8 Further Information: Recording of Data and Selected Resources. 8.1 Recording of Information in the Laboratory. 8.1.1 Introduction. 8.1.2 Examples of Data Sheets. 8.2 Selected Resources. 8.2.1 Keeping 'Up-to-Date'. 8.2.2 Basic Understanding of Inductively Coupled Plasma Spectroscopy (and Related Issues). Responses to Self-Assessment Questions. SI Units and Physical Constants. Periodic Table. Index.
- Volume
-
pbk. : alk. paper ISBN 9780470093498
Description
The book provides an up-to-date account of inductively coupled plasmas and their use in atomic emission spectroscopy and mass spectrometry. Specific applications of the use of these techniques are highlighted including applications in environmental, food and industrial analysis. It is written in a distance learning / open learning style; suitable for self study applications. It contains contain self-assessment and discussion questions, worked examples and case studies that allow the reader to test their understanding of the presented material.
Table of Contents
Series Preface. Preface.
Acronyms, Abbreviations and Symbols.
About the Author.
1. Methodology for trace elemental analysis.
1.1 Introduction.
1.2 Analytical terms and their definition.
1.3 Units.
1.4 Calibration strategies.
1.5 Quality assurance and the use of certified reference materials.
2. Sample preparation for inductively coupled plasma spectroscopy.
2.1 Introduction.
2.2 Aqueous samples.
2.2.1 Liquid-liquid extraction.
2.2.2 Ion exchange.
2.2.3 Co-precipitation.
2.3 Solid samples.
2.3.1 Decomposition techniques.
2.3.2 Microwave digestion.
2.3.3 Dry ashing.
2.3.4 Fusion.
2.4 Extraction procedures.
2.4.1 Single extraction procedures.
2.4.2 Sequential extraction procedures.
2.4.3 Enzymatic digestion procedures.
3. Sample introduction for inductively coupled plasmas.
3.1 Introduction.
3.2 Nebulizers.
3.3 Spray Chambers and desolvation systems.
3.4 Discrete sample introduction.
3.5 Continuous sample introduction.
3.6 Hydride and cold vapour techniques.
4. The inductively coupled plasma and other sources.
4.1 Introduction.
4.2 Inductively coupled plasma.
4.3 Direct current plasma.
4.4 Microwave induced plasma.
4.5 Glow discharge.
5. Inductively coupled plasma - atomic emission spectroscopy .
5.1 Fundamentals of spectroscopy.
5.1.1 Origins of atomic spectra.
5.1.2 Spectral line intensity.
5.1.3 Spectral line broadening.
5.2 Plasma spectroscopy.
5.3 Spectrometers.
5.3.1 Sequential .
5.3.2 Simultaneous.
5.4 Detectors.
5.5 Interferences.
6. Inductively coupled plasma mass spectrometry.
6.1 Introduction.
6.2 Principle of operation.
6.2.1 Ion source: ICP.
6.3 Interface.
6.4 Mass spectrometer.
6.4.1 Quadrupole mass spectrometer.
6.4.2 Sector field mass spectrometer.
6.4.3 Ion trap mass spectrometer.
6.4.4 time-of-flight mass spectrometer.
6.5 Detector.
6.6 Interferences .
6.6.1 Isobaric interferences.
6.6.2 Molecular interferences.
6.6.3 Remedies for molecular interferences.
6.6.4 Non-spectral interferences: matrix-induced.
6.6.5 Remedies for non-spectral interferences.
6.7 Isotope Dilution Analysis.
6.8 Mass spectral interpretation.
7. Selected applications.
7.1 Forensic Science: Document analysis.
7.2 Industrial Analysis: Coal.
7.3 Clinical / Biological Analysis: Whole blood and urine .
7.4. Materials Analysis: Gadolinium Oxide.
7.5. Environmental Analysis: Soil .
7.6. Food Analysis: Milk products.
7.7. Pharmaceutical Analysis.
8. Further Information.
8.1 Recording of information in the laboratory.
8.2 Selected resources.
8.2.1 Keeping up-to-date.
8.2.2 Basic understanding of inductively coupled plasma spectroscopy (and related issues)..
Appendix: Self assessment questions and responses.
Responses to Self-Assessment Questions.
Bibliography.
Glossary of Terms.
SI Units and Physical Constants.
Periodic Table.
Index.