Minimum design loads for buildings and other structures
Author(s)
Bibliographic Information
Minimum design loads for buildings and other structures
(ASCE standard)
American Society of Civil Engineers : Structural Engineering Institute, c2013
- : pbk
Available at 2 libraries
  Aomori
  Iwate
  Miyagi
  Akita
  Yamagata
  Fukushima
  Ibaraki
  Tochigi
  Gunma
  Saitama
  Chiba
  Tokyo
  Kanagawa
  Niigata
  Toyama
  Ishikawa
  Fukui
  Yamanashi
  Nagano
  Gifu
  Shizuoka
  Aichi
  Mie
  Shiga
  Kyoto
  Osaka
  Hyogo
  Nara
  Wakayama
  Tottori
  Shimane
  Okayama
  Hiroshima
  Yamaguchi
  Tokushima
  Kagawa
  Ehime
  Kochi
  Fukuoka
  Saga
  Nagasaki
  Kumamoto
  Oita
  Miyazaki
  Kagoshima
  Okinawa
  Korea
  China
  Thailand
  United Kingdom
  Germany
  Switzerland
  France
  Belgium
  Netherlands
  Sweden
  Norway
  United States of America
Note
"ASCE/SEI 7-10."
Includes bibliographical references and index
"Third printing, incorporating errata identified through March 15, 2013. Also includes Supplement 1 and expanded seismic commentary"
"This document uses both the International System of Units (SI) and customary units"
Description and Table of Contents
Description
Prepared by the Committee on Minimum Design Loads for Buildings and Other Structures of the Codes and Standards Activities Division of the Structural Engineering Institute of ASCE.
Minimum Design Loads for Buildings and Other Structures, ASCE/SEI 7-10, provides requirements for general structural design and includes means for determining dead, live, soil, flood, snow, rain, atmospheric ice, earthquake, and wind loads, as well as their combinations, which are suitable for inclusion in building codes and other documents. This Standard, a revision of ASCE/SEI 7-05, offers a complete update and reorganization of the wind load provisions, expanding them from one chapter into six. The Standard contains new ultimate event wind maps with corresponding reductions in load factors, so that the loads are not affected, and updates the seismic loads with new risk-targeted seismic maps. The snow, live, and atmospheric icing provisions are updated as well. In addition, the Standard includes a detailed Commentary with explanatory and supplementary information designed to assist building code committees and regulatory authorities.
The third printing of Standard ASCE/SEI 7-10 incorporates errata and includes Supplement 1. In addition, the seismic commentary has been expanded and completely revised.
Standard ASCE/SEI 7 is an integral part of building codes in the United States. Many of the load provisions are substantially adopted by reference in the International Building Code and the NFPA 5000 Building Construction and Safety Code.
Structural engineers, architects, and those engaged in preparing and administering local building codes will find the structural load requirements essential to their practice.
by "Nielsen BookData"