  • 新しく試作した新生児用自動制御ECMO装置

    梅田 隆司, 伊藤 喬廣, 瀬尾 孝彦, 伊藤 不二男, 高木 啓之, 鈴木 晃 人工臓器 23 (1), 328-331, 1994

    We developed a new automatically driven blood pump for neonatal extracorporeal membrane oxygenation circuit. Our blood pumps consisted of a pair of sac-typed air driven blood pumps with LED sensors, …

    DOI

  • 次世代の体外循環用装置の開発

    高木 啓之, 岡本 晃〓, 高松 幹夫, 高木 登志子 人工臓器 19 (1), 631-634, 1990

    Left heart assist deviced. eveloped in our laboratory has been substituted for a roller pump in heart lung machine. This system has been tested in mock circulation and in 7 dogs in total …

    DOI

  • プラスチック製補助人工心臓用ボール弁の開発

    永瀬 敏夫, 依田 隆一郎, 福留 明, 仁田 新一, 佐藤 尚, 三浦 誠, 片平 美明, 山家 智之, 本郷 忠敬, 香川 謙, 毛利 平, 井街 宏, 高木 啓之 人工臓器 19 (1), 315-318, 1990

    A plastic ball valve which is aimed to have quantity production, lower cost and antithrombogenicity for a ventricular assist device (VAD) was designed and evaluated in the mock circulation and in …

    DOI 医中誌

  • 新しい体外循環方法の試み

    早川 政史, 間部 弘, 高木 啓之 人工臓器 19 (1), 468-471, 1990

    Double chambered alternate pumping system developed in our laboratory has been substituted as a roller pump in extracorporeal circulation in 5 dogs. Since this pump responds to the venous return …

    DOI

  • 新生児用補助心臓の研究

    高木 啓之, 岡本 晃〓, 高松 幹夫, 高木 登志子 人工臓器 19 (1), 164-167, 1990

    Miniaturized left ventricular assist device in which the chamber has 3-5 ml in capacity and the orfice of the ballvalve has 4 mm in diameter has been tested in 35 dogs. In these experiments, the …

    DOI

  • ECMO(臨床と実験的研究)

    久野 克也, 顔 邦男, 家永 徹也, 沢村 敏郎, 松田 昌三, 岡田 昌義, 中村 和夫, 瀬尾 孝, 伊藤 喬廣, 飯尾 賢治, 高木 啓之, 片山 正夫, 土田 嘉昭, 宮坂 勝之, 鎌田 振吉, 奥山 宏臣, 長谷川 利路, 窪田 昭男, 井村 賢治, 岡田 正, 津田 峰行, 長屋 昌宏, 江崎 正和, 原田 徹, 青野 眞治 日本外科系連合学会誌 1989 (20), 12-27, 1989

    DOI Web Site

  • 新生児用補助人工心臓の開発  慢性実験結果

    岡本 晃榿, 間瀬 武則, 高木 啓之, 高木 登志子 人工臓器 18 (2), 588-591, 1989

    Baby size left ventricular assist device has been developed and tested in our laborarory in dogs. The device has the chamber of 6ml, 5ml, and 3ml in capacity and the valve of 4mm in inner diameter. …

    DOI

  • 人工心臓の新しい自動制御理論

    高木 啓之, 岡本 晃〓, 高松 幹夫, 佐藤 元美, 高木 登志子 人工臓器 17 (3), 1041-1044, 1988

    New system consists of 2 parts, 1 is the timing control unit which turn the solenoid valve on or off in responce to the distance between the housing and the chamber wall. 2 is the air-pressure …

    DOI

  • 小型,軽量,全自動化の多目的血液ポンプ系

    高木 啓之, 岡本 晃〓, 間瀬 武則, 佐藤 元美, 高木 登志子 人工臓器 17 (3), 1045-1049, 1988

    In our automatic control unit of double chambered alternate pumping system, puls moter-air regulator unit provided for automatic control of the air-pressure has been swithed to the “electro-air …

    DOI 医中誌

  • 左房,左室  大動脈同時バイパス法の改良

    高木 啓之, 高木 登志子 人工臓器 14 (3), 1091-1094, 1985

    Modification of 1-atrio and 1-ventricular---aortic bypass (Combination bypass): In our original methode of combination bypass, 2 inflow ducts were independently connected to the 1 atrium and the 1 …

    DOI

  • 埋込み型全人工心臓(TAH)の流入弁の検討

    高木 啓之, 高木 登志子, 神納 美紀子, 早川 政史 人工臓器 14 (3), 1235-1238, 1985

    Evaluation of inflow valves of total artificial heart: New system for evaluating the valves has been developed and 3 kinds of inflow valves were tested. Results were as follows; 1) leaflet valve is …

    DOI

  • 犬での埋込式完全人工心臓

    高木 啓之, 高木 登志子, 堀田 寿郎, 成田 伍郎 人工臓器 12 (1), 20-23, 1983

    Total artificial heart in dogs has been designed and fabricated and tested.<br>Characteristic performance were as follows. (1) implantable in dogs, (2) 200ml/kg/min of max. output, (3) feed back …

    DOI 医中誌

  • 自動制御による犬での完全人工心臓の試み

    高木 啓之, 高木 登志子, 成田 伍良, 堀田 寿郎 人工臓器 11 (1), 309-312, 1982

    As we reported in this meeting last year, we have developed new control machine which can regulate the output of the artificial heart precisely according to the amount of the venous return. Now this …

    DOI 医中誌

  • 人工心臓の自動制御

    高木 啓之, 堀田 寿郎, 高木 登志子, 水野 修二郎 人工臓器 9 (6), 1019-1022, 1980

    Under the fixed rate control of our device, (Double chambered alternate pumping paracorporeal device), one chamber works as a atrium, while the other works as a ventricle. Then, their functions are …

    DOI 医中誌

  • 重症左心不全時の左心バイパス

    高木 啓之, 堀田 寿郎, 高橋 虎男, 成田 伍良 人工臓器 8 (6), 658-661, 1979

    Double chambered alternate pumping paracor=poreal device has been tested in dogs of sever mitral regurgitation. They were separated in 2 groups.<br>In the 1st group, the device used had tube-type …

    DOI 医中誌

  • B34 高木式ポンプによる循環維持

    高木 啓之, 成田 伍郎, 堀田 寿郎, 高橋 虎男, 野口 久輝, 渥美 隆之, 青木 紀生 人工臓器 7 (5), 809-812, 1978

    Left ventricular-aortic bypass or left atrio-aortic bypass under the condition of mitral valve destruction have been performed in 25 dogs with sever left heart failure.<br>Left heart failure was …

    DOI 医中誌

  • 補助心臓の左心補助効果について

    高木 啓之, 堀田 寿郎, 成田 伍良, 高橋 虎男, 渥美 隆之, 野口 輝久 人工臓器 7 (6), 1179-1182, 1978

    Left atrio-, or left ventricular aortic bypass have been performed with Takagi's pump (Double-chambered alternate pumping paracorporeal device)in over 200 dogs under various conditions of the left …

    DOI 医中誌

  • Peristaltic Bypass型補助心臓

    高野 久輝, 高木 啓之, 阿久津 哲造 人工臓器 3 (6), 393-401, 1974

    A peristaltic bypass type of left heart assist device, which diverts blood from the left atrium directly to the aorta, has been designed for human adults and large animals such as calves.<br>This …

    DOI 医中誌