Discrete sample introduction techniques for inductively coupled plasma mass spectrometry

著者

    • Beauchemin, Diane

書誌事項

Discrete sample introduction techniques for inductively coupled plasma mass spectrometry

by Diane Beauchemin ... [et al.]

(Comprehensive analytical chemistry, v. 34)

Elsevier, 2000

大学図書館所蔵 件 / 20

この図書・雑誌をさがす

注記

Includes bibliographical references and index

内容説明・目次

内容説明

The book starts with a detailed description of ICP-MS, including quadruple-based, sector-based and time-of-flight instruments. Instrumentation from existing manufacturers is described and compared to show their similarities and differences. Also, a review of the ICP-MS literature is carried out to outline both the strengths and limitations of the technique, whatever its brand, as well as what it can currently accomplish in terms of applications. Then, the book demonstrates how these limitations can be reduced and/or eliminated by combining various techniques with ICP-MS. Great detail is provided on each technique so that the reader can get a good understanding of it before carrying on to the instrumental requirements for its hyphenation to ICP-MS, and the resulting impact on the operation of the hyphenated instrument. Since this book is concerned with the ICP side only, which is fairly similar in all the instruments from the different manufacturers, the information should be useful to all ICP-MS users. The features and limitations of each technique are thoroughly discussed and illustrated with a review of the ICP-MS literature. Approaches which could be used but have not yet been tried with ICP-MS are also suggested. This is particularly true of flow injection techniques which are extremely flexible and have been used extensively in atomic spectroscopy and spectrophotometry. Many of the features of the technique have not yet been combined to ICP-MS, and one purpose of the book will be to point out potentially beneficial combinations.

目次

Series Editors Preface. Authors' Preface. Current status of ICP-MS. Flow injection techniques. Electrothermal vaporization sample introduction for inductively coupled plasma-mass spectrometry. Laser ablation for inductively coupled plasma-mass spectrometry. Direct sample insertion. Index.

「Nielsen BookData」 より

関連文献: 1件中  1-1を表示

詳細情報

  • NII書誌ID(NCID)
    BA50002136
  • ISBN
    • 0444899510
  • 出版国コード
    ne
  • タイトル言語コード
    eng
  • 本文言語コード
    eng
  • 出版地
    Amsterdam ; Tokyo
  • ページ数/冊数
    xviii, 575 p.
  • 大きさ
    24 cm
  • 親書誌ID
ページトップへ